Mount a screw-terminal electrolytic capacitor with its pressure-relief path unobstructed and tighten its electrical connections only to the limits in the exact part drawing. For comparison, TDK's general guidance gives maximum capacitor-thread torques of 2.5 N·m for M5 and 4.0 N·m for M6 under stated thread-depth conditions; these are TDK reference values, not LORIDA specifications [1]. The practical decision is therefore about orientation, vent clearance, lug fit, and a documented torque limit together. This guide turns those checks into a drawing review and sample-inspection workflow for OEM buyers.
Last Updated: November 25, 2026. No individual author or reviewer is named because a verified public byline identity was unavailable. The product photographs show real LORIDA stock; markings visible in a photo do not establish the specification of every offered series.
Key Takeaways
What the buyer should decide before assembly
Identify the actual vent position and mounting orientation in the selected capacitor's drawing. TDK recommends upright mounting for its screw-terminal capacitors [1].
Ask for the thread, usable depth, lug stack, washer arrangement, and series-specific torque limit before releasing an assembly instruction.
Reserve an unobstructed vent path. Nichicon's general example calls for at least 5 mm above the vent on cases 40 mm or larger [2]; use the selected product's drawing as the controlling requirement.
Do not transfer another manufacturer's torque, clearance, or orientation values to a LORIDA part without a matching specification.

Why mounting position and vent access matter
Find the relief device on the exact construction
Large aluminum electrolytic capacitors are polarized components. Their can, end seal, terminals, and pressure-relief device form a mechanical system, not merely a pair of electrical contacts. A vent must be able to release pressure if the capacitor is subjected to an abnormal condition. A nearby busbar, shelf, bracket, potting compound, or cable loom can occupy the space the vent needs. The enclosure drawing should show the vent-facing side and nearby obstructions so that a design review can resolve this before any prototype is wired.
TDK says screw-terminal capacitors with cover-disk vents should not face terminals down unless the product specification permits it. For horizontal mounting, TDK places the vent at 12 o'clock and still prefers upright installation [1]. Nichicon gives a separate end-seal-up rule for its screw-terminal units [2]. These manufacturer-specific rules are questions for the LORIDA drawing review, not universal permissions.
Define clearance from the actual vent, not from the can edge
Measure the free distance above the pressure-relief feature along its likely release path. Nichicon lists illustrative minimum clearances of 2 mm for case diameters 6.3–16 mm, 3 mm for 18–35 mm, and 5 mm for 40 mm and above [2]. A large screw-terminal can may fall in the last group, but the package drawing and the enclosure geometry must still be checked. A 5 mm gap around a cable lug is not the same as 5 mm above a vent. Record the obstruction, the measurement datum, and the selected part number in the inspection report.
How to set a defensible terminal-torque instruction
Separate capacitor limits from accessory limits
A terminal joint has several distinct parts: the capacitor's internal thread or stud, the screw or nut, a lug or busbar, and any washer or spacer. TDK states that its maximum torque values apply to the capacitor's threads or studs and that an accessory may have a lower limit [1]. The assembly torque must therefore respect the lowest applicable approved limit. Ask the supplier to identify the exact part drawing and the accessory drawing; then document the tool, socket, and target value used on the line.
| TDK reference interface [1] | Maximum capacitor torque | Condition stated by TDK | Buyer action |
|---|---|---|---|
| M5 thread | 2.5 N·m | Thread depth at least 8 mm | Check depth and accessory limit. |
| M6 thread | 4.0 N·m | Thread depth at least 9.5 mm | Check drawing and lug stack. |
| M12 mounting stud | 10.0 N·m | TDK general table | Do not confuse stud torque with terminal torque. |
Inspect the connection without using the capacitor as a fixture
Confirm that the lug sits flat and cannot rotate into a neighboring terminal or vent area. Verify that the screw engages the intended thread without bottoming out before the lug is clamped. A busbar should not impose bending or torsion on the capacitor terminals when the enclosure warms or vibrates. In a prototype, photograph the as-built joint, record the torque tool and calibrated setting, and check polarity before applying power. This is a process-control recommendation, not a claim that the photographed LORIDA unit passed any particular test.

How to turn the checks into an RFQ and acceptance plan
Send geometry and duty data together
An RFQ that states only capacitance and voltage leaves the mechanical decision unresolved. Send the intended part number, terminal thread and depth if known, busbar or cable-lug thickness, washer stack, enclosure position, vibration condition, and a drawing of nearby obstacles. Include the electrical duty—normal and peak DC voltage, RMS ripple current and frequency content, ambient and hot-spot temperature assumptions, and expected service interval—because mounting can change thermal conditions. The LORIDA screw-terminal capacitor category is a starting point for available configurations; the selected model's approved drawing controls the installation.
For DC-bus component selection beyond mounting, see the related VFD DC-bus capacitor RFQ guide. It covers voltage, ripple, and cooling data that must accompany a mechanical request. Buyers can then use the contact page to send the exact assembly drawing and operating profile instead of asking for a generic torque value. Confirm the destination link in the live site before relying on it.
Accept samples with observable checks
An RFQ needs the part number, thread and depth, lug thickness, washer stack, enclosure position, and obstacles near the vent. Add normal and peak DC voltage, RMS ripple and frequency, ambient temperature, airflow, and duty cycle so mechanical and thermal choices can be reviewed together. The LORIDA screw-terminal capacitor category shows available starting configurations; the selected model drawing controls installation.

Frequently asked questions
Can I use a 4.0 N·m setting on every M6 screw-terminal capacitor?
No. TDK's 4.0 N·m value is a maximum for its capacitor thread under the stated minimum thread-depth condition, not a universal setting for all M6 capacitors [1]. The mating lug, washer, screw, or busbar may have a lower mechanical limit, and a different capacitor series may specify another torque. Ask for the exact capacitor and accessory drawings, identify the permitted clamping stack, and set a production target that respects every applicable limit. If the drawing omits torque or engagement depth, pause the instruction and request a written clarification. Do not infer a safe value from thread size alone.
May I mount a screw-terminal capacitor horizontally?
Sometimes, but only when the selected series drawing and the enclosure design permit it. TDK's general guidance prefers upright mounting and places the cover vent at approximately the 12 o'clock position for horizontal mounting [1]. Nichicon's general note also gives a horizontal orientation rule for its screw-terminal units [2]. Those documents describe their own constructions; they do not establish a blanket rule for every LORIDA part. Show the proposed orientation, vent position, and obstacles on the assembly drawing, then obtain model-specific approval. After installation, verify that the vent path remains open and that cables or brackets do not load the terminals.
How much empty space should I leave above the vent?
Use the selected capacitor's drawing first. Nichicon's general example calls for at least 5 mm above a pressure-relief vent when the case diameter is 40 mm or larger, with smaller examples of 3 mm for 18–35 mm and 2 mm for 6.3–16 mm [2]. These dimensions describe a minimum free path above the relief feature, not a generic gap around the sleeve or between cable lugs. A busbar, cover, potting material, or wiring harness may still obstruct venting even if the can has space at its sides. Measure the actual assembly and record the datum used.
Sources and next step
Reference scope
[1] TDK Electronics, Aluminum Electrolytic Capacitors: General Technical Information, section 11, mounting positions and torques. [2] Nichicon, General Descriptions of Aluminum Electrolytic Capacitors, application and mounting guidelines. Values are attributed to these manufacturers and are not LORIDA product specifications.