Match the PCB holes and polarity to the controlled snap-in capacitor drawing before release. A capacitance and voltage match does not establish a mechanical match. LORIDA's KN product page lists a 680 µF, 400 V DC snap-in option but expressly leaves the exact can size and pin-out to the ordered rating drawing [1]. This guide turns that boundary into a buyer and PCB engineer checklist, using clearly labeled Nichicon examples only to show why a generic footprint is unsafe [2][3].

Key Takeaways
What to lock before PCB release
Get the exact ordered series, can diameter, height, pin count, pitch, polarity and auxiliary-terminal map on one controlled drawing [1].
Confirm hole spacing against the actual leads, then check assembly seating and the pressure-relief path [2].
Treat another manufacturer's footprint dimensions as examples, never as LORIDA KN dimensions [1][3].
Why a two-pin outline can still mislead
Pin count and auxiliary terminals need an electrical map
Some snap-in constructions use extra terminals for mechanical support. An auxiliary pin is not automatically a safe power connection. Nichicon's guidelines require isolation between the auxiliary terminal of specified can styles, the positive and negative terminals, and the circuit pattern [2]. The LORIDA part's auxiliary arrangement must be read from its own drawing and approved sample. Record which pads are positive, negative, mechanical only or unused. This is especially important on replacement boards where an old manufacturer's pin pattern may look similar but assign a different function.

Build the footprint from a controlled drawing
Transfer dimensions without assuming a standard pitch
Start with the exact part number and drawing revision. Transfer the can diameter, maximum sleeve envelope, terminal count, hole diameter, pitch, angular orientation and tolerances into the PCB library. Nichicon's LAS drawing is a useful contrast: its example shows two 2.0 ± 0.1 mm PCB holes at 10 ± 0.1 mm spacing and a 4.0 ± 0.5 mm terminal projection [3]. These figures belong to Nichicon LAS, not LORIDA KN. They demonstrate why a rounded “10 mm snap-in” label cannot replace a vendor drawing and tolerance check.
Verify polarity, vent and nearby copper together
Keep the polarity bar, board symbol, assembly drawing and incoming-inspection photograph consistent. Nichicon instructs designers to match PCB hole spacing to capacitor leads, keep circuit pattern and wiring away from the pressure-relief vent, and create an aligned board opening when a vent faces the PCB [2]. It also says the outer sleeve is not guaranteed electrical insulation [2]. The exact LORIDA vent position, clearance and insulation scheme must be approved from the ordered series documentation. A vent-clearance checklist is available in our electrolytic capacitor PCB vent guide.
| Release item | Evidence to compare | Do not infer from |
|---|---|---|
| Can envelope | Exact LORIDA series drawing and sample | Capacitance/voltage headline |
| Pin count, pitch and hole size | Controlled terminal drawing with tolerances | Another manufacturer's 10 ± 0.1 mm example [3] |
| Polarity and auxiliary pins | Pin-function map and incoming sample | Photograph alone |
| Vent and insulation | Approved vent position and equipment clearance | Sleeve color or generic case size [2] |
| Assembly fit | First-article PCB and solder inspection | CAD fit alone |

Qualify the real assembly, not only the CAD model
Check seating and insertion stress
Nichicon says snap-in can capacitors of its specified JIS styles should sit tightly against the PCB, without a gap beneath the body [2]. That is a manufacturer installation instruction, not a blanket rule for every LORIDA part. During first-article assembly, photograph the body seating, inspect the terminals before and after insertion, and confirm that insertion or clinching force does not load the can. A hole pattern that can be forced into place is not an approved fit. Reject damage to the sleeve, seal, pins or vent.
Send an RFQ that can be approved
State the full electrical and mechanical envelope
For the 680 µF / 400 V KN reference, the LORIDA page lists a 2,000 h endurance at 105°C with rated ripple current and a 1,000 h shelf-life reference at 105°C, subject to series recovery conditions [1]. Those are catalog test statements, not a prediction of application life. Request the current series file for the exact can size, ripple-current rating, leakage criterion, terminal drawing and marking. Add DC-bus voltage, ripple spectrum, ambient, airflow, expected life and vibration. The same request can link to the LORIDA KN snap-in product reference.
Frequently Asked Questions
Can I use a 10 mm snap-in footprint for every 680 µF / 400 V capacitor?
No. A 10 mm pattern is not universal for that electrical rating. Nichicon LAS publishes an example 10 ± 0.1 mm hole spacing with two 2.0 ± 0.1 mm holes [3], while the LORIDA KN product page says its exact terminal geometry follows the ordered rating option and controlled drawing [1]. Confirm the selected part number, terminal count, pin pitch, hole diameter, tolerances and polarity before releasing copper. Then test the first approved sample on the production PCB without forcing the leads. Keep the library and drawing revision tied to the purchasing code, so a later supplier or case change triggers another mechanical review.
Can a snap-in auxiliary pin be tied to the negative pad?
Only if the controlled drawing for the exact part explicitly permits that connection. A support terminal may be mechanically useful but electrically isolated; Nichicon's application guidelines require isolation for auxiliary terminals of specified can styles [2]. Do not infer the function from the number of pins or from a photograph. Ask for a pin-function map that labels positive, negative and auxiliary terminals, and compare it with a sample and board netlist. Keep any mechanical-only pad isolated from active copper as directed by the series document. During first-article inspection, confirm solder bridges and nearby copper have not changed that intended isolation.
What should I inspect before accepting a snap-in capacitor PCB assembly?
Check fit, polarity, vent path, solder joints and the exact approved part identity. Verify the can marking and purchase code against the drawing, then inspect terminal count, lead-to-hole alignment, body seating, sleeve and seal condition, vent clearance and nearby copper. Nichicon says its specified snap-in can styles should sit tightly on the PCB and warns against force on the body during insertion [2]. Record the actual solder process and inspect for excessive heat, flux on the body, damaged terminals or tilted cans. Finally, compare first-article electrical measurements with the selected LORIDA series criteria rather than a generic catalogue value.
Sources and release decision
Trace the dimensions to the right manufacturer
[1] LORIDA KN 680 µF / 400 V product page. [2] Nichicon Application Guidelines for Aluminum Electrolytic Capacitors. [3] Nichicon LAS snap-in series drawing. Nichicon values are comparison examples, not LORIDA KN ratings or dimensions.
Release the exact footprint
Send the selected part number, controlled drawing, PCB hole map, application duty and sample-inspection plan for a series-specific review.
Contact LORIDA with your PCB and RFQLast Updated: November 26, 2026.