TECHNICAL TEST GUIDE
A film capacitor thermal stability test is passed only when the exact part remains thermally settled and its electrical parameters stay within the specified post-test limits under the defined overload condition. A temperature reading by itself is not enough; the lab must control power, frequency, cooling, measurement position, duration and before/after electrical data.
Key Takeaways
Define the applicable series, standard clause and rated conditions before testing.
Measure ambient, case temperature and electrical load at named locations.
Confirm temperature has stabilized rather than relying on one late reading.
Compare capacitance and dissipation factor before and after the test.
Use the real assembly as a separate validation; a component test is not a system approval.
What does thermal stability mean?
Heat generation must reach a controlled equilibrium
Film capacitors generate heat through dielectric and conductor losses. The operating temperature is the ambient temperature plus self-heating. TDK’s general film-capacitor guidance expresses this as Top = TA + ΔT and requires operating temperature to remain at or below the upper category temperature. This makes the test a balance between internally generated loss and heat released to the surroundings.
The result is series-specific. TDK’s B32754–B32758 metallized polypropylene family, for example, lists a case operating range from −40 °C to +105 °C, a rated temperature of +85 °C, and voltage derating above 85 °C of 1.5% per °C. These figures describe that named family; they are not universal specifications for every film capacitor or every LORIDA option.
A marked standard number is not the whole acceptance plan
A product marking such as IEC 61071 identifies a design or test context but does not, by itself, prove that a supplier, factory or finished system holds every certification a buyer may require. The purchase specification must name the exact part, edition or customer procedure, test circuit, sample size, preconditioning, permissible parameter change and required evidence.
Six acceptance checks for the lab plan
1–3: load, environment and temperature
Lock the electrical load. Record RMS voltage, current, frequency, waveform and real power. TDK’s published B32754–B32758 type-test table gives a thermal-stability overload condition of 1.21 × Pmax, with the referenced loss measurement at 10 kHz. Apply this only when the selected series and agreed procedure call for it.
Control cooling and ambient. The same type-test description specifies natural cooling with ambient held within ±5 °C. Document chamber condition, airflow, spacing, fixture orientation and heat from neighboring samples so another lab can reproduce the setup.
Measure temperature consistently. Define sensor type, attachment method and case location. A heavy thermocouple, reflective surface or loose tape can bias the reading. Record ambient and case temperature together, because a case value without its ambient reference cannot show self-heating.
4–6: duration, electrical drift and evidence
Run long enough to demonstrate stability. TDK’s cited table uses a 48-hour duration and calls for temperature measurement every 1.5 hours during the final 6 hours. A flat trend is stronger evidence than a single endpoint.
Check post-test parameters. The cited acceptance criteria include temperature rise below 1 °C over the evaluation interval, capacitance change |ΔC/C0| ≤2%, and dissipation-factor increase at 10 kHz no greater than 1.2 times the initial value plus 0.015. Record actual values, not only “pass.”
Preserve traceability. Link each sample to part number, lot, drawing, calibration IDs, raw data, photos, test start and stop times, operator and review signature. Deviations need written disposition before the result is used for approval.
| Control | Record before test | Record during/after test | Release question |
|---|---|---|---|
| Electrical load | C, tan δ, voltage, current, frequency | Waveform and real load | Was the specified overload reached? |
| Thermal | Ambient, sensor and position | Time-series case and ambient data | Did the trend stabilize? |
| Post-test | Initial values and limits | ΔC, Δtan δ, visual condition | Are all limits met? |
| Traceability | Lot, sample IDs, calibration | Raw files, photos, deviations | Can the result be reproduced? |
How to avoid false passes and false failures
Separate measurement error from component behavior
A drifting ambient, intermittent current, sensor detachment or incorrect dissipation-factor frequency can make a stable part look unstable—or hide a real problem. Review raw time stamps, calibration validity and instrument range. Measure capacitance and tan δ after the specified recovery period under the same conditions used for the initial reading. Photograph cracks, swelling, leakage, terminal discoloration and fixture contact.
Use more than one sample when the qualification plan requires evidence of production consistency, and keep the fixture identical across the set. If one curve separates from the others, investigate its electrical load, sensor contact and sample identity before averaging results. An average can hide an unstable unit. The report should therefore retain every individual trace, the ambient trace and any interruption or instrument-range change. This makes the acceptance decision auditable and helps engineering distinguish a repeatable construction issue from a one-off setup error.
Do not substitute the component test for application validation
TDK’s CLARA guidance notes that self-heating estimates are based on laboratory testing with natural cooling and a single capacitor, without other nearby heat sources, and recommends real-application testing when conditions approach limits. In an inverter, charger or pulse circuit, busbar heat, enclosure airflow, harmonic current and mounting orientation may change the thermal result. Qualify both the component procedure and the final assembly.
Frequently asked questions
Is a stable case temperature enough to pass the test?
No—the electrical parameters and the defined acceptance limits must also pass. A capacitor can reach thermal equilibrium yet show excessive capacitance loss, increased dissipation factor or visible damage. Record the temperature trend, actual overload, pre- and post-test capacitance, tan δ and appearance. The applicable datasheet or agreed customer plan must define recovery time and limits. A single temperature reading without load and ambient records is not auditable evidence.
Can the IEC 61071 marking be treated as a LORIDA certification?
No—the marking should not be converted into a company-wide certification claim. It may indicate the design or test basis stated for that product, but the buyer still needs the exact datasheet, declaration, report scope and supplier confirmation. Certification, conformity and laboratory accreditation are separate questions. Keep the claim limited to verified documents for the exact part and do not infer approval for another series or the finished equipment.
Where should the temperature sensor be placed?
Place it at the manufacturer- or plan-defined case hot spot and document the position. The sensor should have reliable contact without becoming a major heat sink. Keep it away from forced airflow that does not represent the part surface, and use the same attachment method for every sample. When the likely hot spot is uncertain, a thermal survey can identify candidates before the controlled measurement points are fixed.
What should a buyer request with the test report?
Request the procedure, raw time-series data and traceable sample information—not only a pass statement. The package should include part and lot numbers, sample count, circuit, voltage, current, frequency, ambient, fixture, cooling, sensor location, calibration IDs, initial and final C/tan δ, visual results, deviations and reviewer approval. Ask whether the test represents the exact ordered construction and whether any design or material change triggers requalification.
Sources and next step
Primary references
TDK Electronics, Film Capacitors: General Technical Information.
TDK Electronics, B32754–B32758 metallized polypropylene datasheet.
TDK Electronics, CLARA design-tool guidance.
Prepare a test-ready film capacitor RFQ
Send the exact circuit waveform, voltage, current spectrum, ambient range, cooling and acceptance evidence required.
Explore film capacitor options · Review RMS current checks · Contact LORIDA
Last Updated: November 23, 2026